Secondary / Biological Treatment

Part of Intro to Industrial Wastewater Treatment.

Biology is the right tool when a useful share of the COD is biodegradable, the water is not toxic to the biomass, and the temperature is one that the organisms can live in. It is the wrong tool for a metals stream, a brine, or a solvent dump.

Activated sludge

Microorganisms are kept in suspension, fed with the wastewater and supplied with oxygen. A clarifier settles them and returns most of the sludge to the aeration tank. Variants match the factory:

  • Conventional. A balance of tank volume, oxygen and sludge age for a steady organic load.
  • Extended aeration. A longer sludge age, less excess sludge, more oxygen. Forgiving, and hungry for air.
  • SBR (sequencing batch reactor). Fill, react, settle and decant in one tank. A practical fit when flow arrives in batches.

MBBR

A moving-bed biofilm reactor grows the biomass on plastic carriers that are kept in motion. The process is compact and often copes with load swings better than a fragile suspended culture. Carriers do not replace a solids separation step. Something still has to catch the solids that leave the reactor.

MBR

A membrane bioreactor is activated sludge with membranes in place of the clarifier. Effluent solids are very low, the sludge age can be long, and the water is a better feed to reuse. The membranes need air scour, cleaning and a feed that is not full of fat, hair or grit. An MBR is a biological process and a membrane process at the same time.

Anaerobic systems: UASB and EGSB

Anaerobic granules convert a large share of biodegradable COD to biogas, with little excess sludge and no aeration. A UASB (upflow anaerobic sludge blanket) and an EGSB (expanded granular sludge bed) are the common high-rate forms. EGSB runs at a higher upflow velocity so the bed expands.

They suit warm, high-strength, biodegradable water: many food, beverage, brewery and some pulp or chemical streams. They are a poor fit for cold, very dilute, or toxic water unless that water is pretreated and heated. Anaerobic effluent still holds nutrients and a residual oxygen demand, so an aerobic polish is the normal next step. The biogas is the energy reason for choosing this route.

Nutrient removal

Nitrogen removal is nitrification (oxygen, alkalinity, enough sludge age) followed by denitrification (an anoxic zone and a carbon source). Phosphorus is removed biologically or by precipitation with iron or aluminium salts. Industrial plants sometimes have the opposite problem: plenty of carbon and almost no nitrogen or phosphorus, so nutrients are dosed to keep the biomass alive. High salt, sudden biocides and cold water are the usual reasons a nutrient step looks “broken” when the biology itself has stalled.

Back to the knowledge centre

In the webshop: diffusers. dabce.se/shop